Two key challenges facing Natural Gas Engines used for cogeneration purposes are spark plug 
life and high NOx emissions. Using Hydrogen Assisted Lean Operation (HALO), these two 
keys issues are simultaneously addressed. HALO operation, as demonstrated in this project, 
allows stable engine operation to be achieved at ultra-lean (relative air/fuel ratios of 2) conditions, which virtually eliminates NOx production. NOx values of 10 ppm (0.07 g/bhp-hr NO) for 8% (LHV H2/LHV CH4) supplementation at an exhaust O2 level of 10% were demonstrated, which is a 98% NOx emissions reduction compared to the leanest unsupplemented operating condition. Spark ignition energy reduction (which will increase ignition system life) was carried out at an oxygen level of 9 %, leading to a NOx emission level of 28 ppm (0.13 g/bhp-hr NO). The spark ignition energy reduction testing found that spark energy could be reduced 22% (from 151 mJ supplied to the coil) with 13% (LHV H2/LHV CH4) hydrogen supplementation, and even further reduced 27% with 17% hydrogen supplementation, with no reportable effect on NOx emissions for these conditions and with stable engine torque output. Another important result is that the combustion duration was shown to be only a function of hydrogen supplementation, not a function of ignition energy (until the ignitability 
limit was reached). The next logical step leading from these promising results is to see how much the spark energy reduction translates into increase in spark plug life, which may be accomplished by durability testing.

More info

Schreiben Sie einen Kommentar

ZUM ERSTEN MAL HIER? Hole dir JETZT deinen 10% Gutschein für deinen Ersteinkauf!

Trage einfach eine Email Adresse ein und wir senden dir deinen Gutscheincode direkt in dein Email Postfach

Deine Email Adresse eingebenDeinen Vornamen eingeben